Five troubleshooting methods of sealing machine
1. The screw clamping action of the sealing machine is too slow or the clamping screw travel is insufficient: the bolt is loose, and the front buckle or inner plate of the board machine are worn. At this time, the bolt can be tightened, and the front buckle or inner plate of the board machine can be replaced. After the above actions are completed, test its function. If the travel is too short, fine tune the front buckle shaft upward; if the action is slow, fine tune the front buckle shaft downward;
2. Air leakage at piston rod of sealing machine failure: the ring at the bottom of the main body is damaged, so the ring should be replaced;
3. Air leakage at the exhaust port: the on-off valve ring or switch seat ring is damaged or the piston ring is damaged. Replace the ring;
4. Air leakage at the trigger of sealing machine: the on / off valve ring or switch seat ring is damaged. Replace the ring;
5. The transmission ring is loose and cannot be positioned: the plastic steel bar and the transmission spring are inelastic. Remove the board computer combination and replace the spring tip or replace the plastic steel bar and transmission spring.